<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SMS/GPRS Remote Data Logger &#8211; Tara Asia Co.,Ltd</title>
	<atom:link href="http://taraasia.co.th/product-tag/sms-gprs-remote-data-logger/feed/" rel="self" type="application/rss+xml" />
	<link>http://taraasia.co.th</link>
	<description>Tara Asia Co.,Ltd</description>
	<lastBuildDate>Wed, 10 Jun 2020 03:57:01 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>http://taraasia.co.th/wp-content/uploads/2020/05/cropped-tempsnip-32x32.jpg</url>
	<title>SMS/GPRS Remote Data Logger &#8211; Tara Asia Co.,Ltd</title>
	<link>http://taraasia.co.th</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>XiLog+ with 3G Communication Data Logger</title>
		<link>http://taraasia.co.th/product/xilog-with-3g-communication-data-logger/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 03 May 2020 14:18:46 +0000</pubDate>
				<guid isPermaLink="false">http://ld-wp.template-help.com/wordpress_62555/4/moving-2/?post_type=product&#038;p=3640</guid>

					<description><![CDATA[Universal tool for both homeowners and experts. Pliers’ rubberised handle prevent them from falling out of hands and hurting you. Bolt cutter and high leverage design are ergonomical and were specially designed and tested for better professional usage.
<h3>Features</h3>
<ul>
 	<li>One, two, three and nine channel models</li>
 	<li>High performance state-of-the-art below ground antenna</li>
 	<li>Data transmission down to every 1 minutes (needs external power)</li>
 	<li>Contact the logger as required</li>
 	<li>Profile alarms with separately defined high and low profiles</li>
 	<li>Wide range of sensors and high accuracy</li>
 	<li>Powered for up to 5 years (depends upon configuration) + external battery and mains powered options</li>
 	<li>Robust and waterproof to IP68</li>
 	<li>SIM easily fitted on-site</li>
</ul>
<h3>จุดเด่น</h3>
<ul>
 	<li>มีให้เลือกตั้งแต่แบบ 1, 2, 3 และ 9 ช่องสัญญาณ</li>
 	<li>ใช้เสาอากาศที่มีสมรรถนะสูงซึ่งสามารถใช้งานใต้ดินได้</li>
 	<li>สามารถส่งข้อมูลได้ความถี่ต่ำสุดถึง ทุก 1 นาที (ต้องใช้แหล่งพลังงานภายนอก)</li>
 	<li>สามารถติดต่อกับอุปกรณ์ได้ตามที่ต้องการ</li>
 	<li>ตั้งสัญญาณเตือนได้โดยกำหนดค่าคงที่สูงสุด-ต่ำสุด (Threshold alarms) หรือตามรูปแบบการใช้น้ำ (Profile alarms) หรือตามความต้องการที่แตกต่างกันในแต่ละช่วงเวลา (Envelop alarms)</li>
 	<li>ใช้กับ sensor ได้หลากหลาย และความเที่ยงตรงสูง</li>
 	<li>แบตเตอรีใช้งานได้นานถึง 5 ปี (ขึ้นอยู่กับการตั้งค่าการทำงาน) และสามารถใช้งานแบตเตอรีภายนอก และไฟ AC ได้</li>
 	<li>แข็งแรง ทนทาน และป้องกันความชื้นและฝุ่นได้ตามมาตรฐานระดับ IP68</li>
 	<li>สามารถใส่ SIM card ได้สะดวก</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h4>Applications</h4>
<ul>
<li>Flow &#8211; district and zone monitoring, leakage detection, consumption monitoring</li>
<li>Network modelling</li>
<li>Pressure monitoring</li>
<li>PRV performance</li>
<li>Reservoir / bore-hole depth</li>
<li>Level / flow conversion on open channel</li>
<li>Rainfall</li>
<li>Overflow detection</li>
<li>Logging</li>
<li>Flexible logging memory and configuration;</li>
</ul>
<p>Memory size; 2 Gbyte<br />
Measurement interval; 1 second &#8211; 24 hour<br />
Logs at different intervals on same input<br />
Logs daily minimum, maximum and totals<br />
Event logging<br />
Data Transfer<br />
All loggers may be configured to use GPRS or SMS remote communications for periodic reporting. Transmission period can be set from 15 minutes to 24 hours. The state-of-the-art antenna enables XiLog+ to operate from below ground in most locations. In areas of poor GSM/GPRS coverage an external antenna option is available.</p>
<p>Flow<br />
The flow input can log two uni-directional flows or one bi-directional flow. Also, both outputs from combination meters can be logged on one logger input channel. Existing meter index value can be entered at start of logging. Operation with, but not limited to, the following flowmeters:</p>
<p>Pressure/Depth/Analogue<br />
Accuracy to ±0.1% (of full scale). The offset of the transducer is corrected by the Auto Zero facility. XiLog 1P, 2i 3i have internal transducers. XiLog 2 accepts a range of electrical inputs or external pressure or depth transducers for monitoring weirs, reservoirs, and boreholes.</p>
<p>XiLog 9 has multiple digital, voltage and current inputs for flexible use in multiple applications.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>XiLog+ waste water sensors</title>
		<link>http://taraasia.co.th/product/xilog-waste-water-sensors/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 22 Apr 2020 02:42:02 +0000</pubDate>
				<guid isPermaLink="false">http://taraasia.co.th/?post_type=product&#038;p=5383</guid>

					<description><![CDATA[The new XiLog+ 2W data logger extends the XiLog+ range for use with more sensors on waste water networks. Applications include permanent monitoring of storm weirs, sewer overflows, network modelling and influence of rainfall and industrial discharges to networks.
<h4>Open channel flow using Doppler sensor</h4>
The Doppler method uses a continuous, ultrasonic signal sent into the water at a known angle to measure the flow velocity. Moving particles generate a frequency shift proportional to the velocity of the particles
<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li>One sensor for Doppler measurement + piezoresistive pressure (depth) measurement +temperature compensation</li>
 	<li>Wedge sensor for mounting on channel bottom</li>
 	<li>For use in slightly to heavily polluted water</li>
 	<li>Flow velocity range; ±600 cm/sec</li>
 	<li>Level range; 0 - 350 cm</li>
</ul>
</li>
</ul>
<h4>Level measurement using ultrasonic sensor</h4>
Ultrasonic pulses are reflected by the surface and received at the sensor. A common application is for depth v flow-rate determination on weirs and flumes.
<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li>Typical application is for monitoring sewer overflows at times of excessive rainfall when sewerage may be discharged into the environment</li>
 	<li> Range up to 3 metres</li>
 	<li> Deviation; ±4 mm or &#60;0.2%</li>
 	<li> 4-20mA interface to logger</li>
</ul>
</li>
</ul>
<h4>Level measurement using radar sensor</h4>
Sensor uses pulsed microwaves enabling high accuracy over a wide range. Furthermore, it is not affected by humidity, surface foam, etc., creating false echoes.
<ul>
 	<li style="list-style-type: none;">
<ul>
 	<li>Accuracy; ± 2 mm (of reading)</li>
 	<li>One device covers wide range (up to 15 metres)</li>
 	<li>No dead-band under sensor (ultrasonic 250mm deadband, 6m range)</li>
 	<li>Not affected by temperature, humidity, surface foam, dust and air movements</li>
 	<li>Low maintenance costs</li>
 	<li>No drift and no recalibration</li>
</ul>
</li>
</ul>
<h4>Overflow sensor</h4>
The overflow sensor is self-powered and, when submerged, indicates presence of water. The system measures the time an overflow occurs, e.g. over a weir. Installation of the sensor is made in the required position to detect an overflow. The sensor has a designed profile to avoid sediment build up.]]></description>
										<content:encoded><![CDATA[<h4>Downloads</h4>
<ul>
<li style="list-style-type: none;">
<ul>
<li><a href="https://www.primayer.com/wp-content/uploads/2017/06/Wastewater-sensors-IXD-650-TN-044-Issue-2.4.pdf" target="_blank" rel="noopener noreferrer">Technical Note – Waste Water Applications (English)</a></li>
<li><a href="https://www.primayer.com/wp-content/uploads/2017/06/Xilog-Wastewater-sensors-IXD-650-TN-2.4-033.pdf" target="_blank" rel="noopener noreferrer">Technical Note – Waste Water Applications (French)</a></li>
<li><a href="https://www.primayer.com/wp-content/uploads/2017/06/Water-Meter-Logging-IXD-603-2.0-044.pdf" target="_blank" rel="noopener noreferrer">Technical Note &#8211; Water Meter Logging (English)</a></li>
</ul>
</li>
</ul>
<h4>Applications include;</h4>
<ul>
<li style="list-style-type: none;">
<ul>
<li>Storm weir overflow</li>
<li>Detection of a tank overflowing</li>
<li>Level detection in waste water chamber</li>
<li>Alarm on threshold of water</li>
</ul>
</li>
</ul>
]]></content:encoded>
					
		
		